Back to overview

CVE-2025-69425

CRITICAL
10.0
CVSS 4.0
Description
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a hardcoded Time-based One-Time Password (TOTP) secret and an embedded static token. An attacker who extracts these credentials from the appliance or a compromised device can generate valid authentication tokens and execute arbitrary OS commands with root privileges, resulting in complete system compromise.

Metadata

CVE ID
CVE-2025-69425
State
PUBLISHED
Assigner
VulnCheck
Reserved
2026-01-08 20:48 UTC
Published
2026-01-09 16:14 UTC
Last updated
2026-07-28 01:48 UTC
Primary CWE
CWE-306
CWE-306 Missing Authentication for Critical Function
Vendor / Product
RUCKUS Networks / vRIoT IoT Controller
Sources
cve.org  ·  NVD

Severity & Metrics

10.0 CRITICAL CVSS 4.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
SSVC — CISA Coordinator
Exploitation
none
Automatable
yes
Tech. Impact
total
Affected products (1)
VendorProductPlatformVersions
RUCKUS Networks vRIoT IoT Controller 2.3.0.0 (GA) < 3.0.0.0 (GA), 2.3.1.0 (MR) < 3.0.0.0 (GA), 2.4.0.0 (GA) < 3.0.0.0 (GA)
Weakness (CWE)
CWESourceDescription
CWE-306 cna CWE-306 Missing Authentication for Critical Function
CWE-798 cna CWE-798 Use of Hard-coded Credentials
CVSS scores (1)
ScoreSeverityVersionSourceVector
10.0 CRITICAL 4.0 cna CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
Back to overview