CVE-2026-34021
HIGH Exploitation: PoC
8.6
CVSS 4.0
Description
The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.
Metadata
Severity & Metrics
8.6
HIGH CVSS 4.0
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N
SSVC — CISA Coordinator
Affected products (1)
| Vendor | Product | Platform | Versions |
|---|---|---|---|
| Wertheim GmbH | Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller) | — | Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320 |
Weakness (CWE)
| CWE | Source | Description |
|---|---|---|
| CWE-294 | cna | CWE-294 Authentication bypass by capture-replay |
CVSS scores (1)
| Score | Severity | Version | Source | Vector |
|---|---|---|---|---|
| 8.6 | HIGH | 4.0 | cna | CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N |